Conexiant
Login
  • The Analytical Scientist
  • The Cannabis Scientist
  • The Medicine Maker
  • The Ophthalmologist
  • The Pathologist
  • The Traditional Scientist
The Medicine Maker
  • Explore

    Explore

    • Latest
    • Features
    • Interviews
    • Business & Trends
    • Technology & Manufacturing
    • Product Profiles
    • White Papers

    Featured Topics

    • Biopharma
    • Small Molecules
    • Cell & Gene
    • Future of Pharma

    Issues

    • Latest Issue
    • Archive
    • Cell and Gene Therapy Supplement
  • Topics

    Topics

    • Drug Discovery
    • Development & Clinical
    • Formulation
    • Drug Delivery
    • Bioprocessing
    • Small Molecules
    • Cell and Gene
    • Facilities & Equipment
    • Outsourcing
    • Packaging
    • Supply Chain
    • Regulation & Standards
  • News & Blogs

    News & Blogs

    • Industry News
    • Research News
    • Blogs
  • Events
    • Live Events
    • Webinars
  • Community & Awards

    Community & Awards

    • Power List
    • Sitting Down With
    • Innovation Awards
    • Company of the Year Awards
    • Authors & Contributors
  • Multimedia
    • Video
    • Podcasts
    • eBooks
Subscribe
Subscribe
The Medicine Maker / Issues / 2016 / Articles / Apr / The Search for the Ideal Detector
Discovery & Development Analytical Science

The Search for the Ideal Detector

Will aerosol-based detectors ever meet all the needs of the pharmaceutical industry?

By Dorina Kotoni 04/25/2016 1 min read

Share

When developing impurity-profiling methods for pharma applications, detection and sensitivity can be challenging. On one hand, the high variability of physico-chemical properties of the analytes requires that we use universal detection systems, while on the other hand the expectations of regulators drive the need for higher sensitivity and detectability (for trace analysis, degradation by-products, and so on). The pharmaceutical industry has been basing most of its release methods on liquid chromatography (LC) with UV detectors and gas chromatography with flame ionization detectors, with the occasional use of fluorescence and mass spectrometry. There is still a reluctance to introduce other “universal detectors”. Moreover, pharma’s “ideal” detector should be sensitive and robust, ideally showing a universal response independently of the properties of the sample. It should be able to detect and quantify all components, including unknowns for which no reference standards are available (which is typically the case for early phase projects). Ease-of-use, the ability to interface with high-performance liquid chromatography (HPLC) and ultra HPLC instruments, cost effectiveness, as well as a good understanding of the response curves, are fundamental for the purchase and implementation of a new detector.

The truth is, although we are promised great things, we are still waiting for a commercially available and truly universal detector! The next best thing to a universal detector, according to instrument manufacturers, is an aerosol-based detector, but, in reality, this only delivers what it promises for detecting non-volatile components under isocratic elution conditions. While there have been significant advances in this field, there is still a lot to be understood in the responses obtained with light scattering and charged aerosol detectors – for example, gradient effects, detector settings, influence of compound properties on the detection. Interestingly, a few recent studies highlight that volatility of a compound is not sufficient to explain differences observed in detection. For non-volatiles and semi-volatiles, parameters such as molar volume and diffusivity, as well as net charge of the compound seem to play a role in detection. These new aspects still need further investigation and explanation by theoreticians and instrument manufacturers. Understanding the response model of aerosol-based detectors under hydrophilic interaction LC (HILIC) conditions can frequently prove even more challenging. Analytes eluted in HILIC often require an alternative detection technique due to low UV absorption (sugars, aliphatic amines, lipids, amino acids). There is ongoing research in the field but so far, most publications describe work done under mainly isocratic elution conditions. In my opinion, we still have a long way to go in understanding aerosol-based detection under HILIC conditions. A HILIC expert once told me “we never use gradients in HILIC, they are too complex”, showing that there is still a big gap to cover, model and understand, both in terms of separation and of detection. A universal response model for non-volatile molecules in HILIC is inherently more complex and needs to consider not only the gradient effects, but also the detector settings, the mobile phase interference, and the polarity of the analytes. Manufacturers need to investigate the fundamentals of nebulization and particle formation further to design detectors with increased sensitivity and greater uniformity in their response. In some cases, it might not be enough to widen the dynamic range of the detector by data interpolation through algorithms introduced between the analog and the digital output of the signal. We need to detect more and better – and I don’t think that, in the case of aerosol-based detection, an algorithm (as refined as it may be) will save the day. I am convinced, however, that when there is a better understanding of the response model for aerosol-based detection under a variety of analytical conditions, the pharma industry will be very happy to introduce them routinely. The need is there. In the meantime, we are still looking for that ideal detector...

This article was originally published in The Analytical Scientist (www.theanalyticalscientist.com), a sister publication to The Medicine Maker.

Newsletters

Receive the latest analytical science news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

About the Author(s)

Dorina Kotoni

Dorina Kotoni is Analytical Expert and Principal Scientist at Novartis, Basel, Switzerland. After gaining an MS in Pharmaceutical Chemistry, Dorina completed her PhD in Pharmaceutical Sciences at the Sapienza University of Rome. First as a PhD student and later as a Post-Doc Fellow in Prof. Gasparrini ’s lab, Dorina’s research focused on the preparation and characterization of chiral stationary phases for enantioselective UHPLC and UHPSFC, as well as on the development of new HILIC materials for rapid speed analysis of carbohydrates. Her interest in both chiral and achiral UHPLC columns, has l ed to a more in-depth study of the parameters influencing chromatographic performance in UHPLC. Dorina is currently working in Novartis with a focus on the HPLC to UHPLC transition and HIL IC method development.

More Articles by Dorina Kotoni

False

Advertisement

Recommended

False

Related Content

Electrifying R&D Acceleration
Small Molecules Analytical Science
Electrifying R&D Acceleration

December 2, 2014

0 min read

Electrochemical reaction cells are finding new applications in the pharma R&D lab that could offer big time and cost savings...

The Lab of the Future: Combining Automation with Digital Tools
Contract Development Services Analytical Science Technology and Equipment Digital Technologies
The Lab of the Future: Combining Automation with Digital Tools

February 25, 2025

6 min read

How do you scale up operations without adding headcount or significantly increasing investment in instrumentation? The answer: automation and workflow scheduling software.

SORS and the Power of Light in Pharma
Ingredients Analytical Science Technology and Equipment
SORS and the Power of Light in Pharma

January 17, 2025

7 min read

Understanding the role of spatially offset Raman spectroscopy in identifying raw materials, counterfeit medicines, and more

Facing Up to the New Nemesis of Pharma: Nitrosamines
Quality & Compliance Small Molecules Process Control Analytical Science Ingredients
Facing Up to the New Nemesis of Pharma: Nitrosamines

September 5, 2024

8 min read

What’s going on with nitrosamines in pharmaceutical products? Naiffer Romero, Principal Scientist at the US Pharmacopeia walks us through frequently asked questions.

The Medicine Maker
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Advertise With Us
  • Contact Us

Copyright © 2025 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.